ULTRACLEAN - Air Systen & Technologies
logo

Products

PREFILTER

Pre filters are used in general air filtration application having medium dust holding capacity, made out from nonwoven synthetic media sandwiched between two layers of HDPE mesh assembled in aluminium frame supported by aluminium rod spacers to make it strong .These filters are washable and cleanable and are used as coarse filter to fine filter and also to protect the coil and HVAC system from dust loading. Available in standard depth of 50 mm. Other sizes are also made as per order. M.O.C is aluminium /G.I./SS304.
GRADE SIZE IN MM CFM CAPACITY INT.PRESSURE DROP % DUST WEIGHT ARREST
EU-2/G2 610 X 610 X 50 2000 2 mm of WG 80
EU-2/G2 305 X 305 X 50 500 2 mm of WG 80
EU-4/G4 610 X 610 X 50 2000 4 mm of WG 90
EU-4/G4 305 X 305 X 50 500 4 mm of WG 90

MICROVEE OR FINE FILTER

Pre filters are used in general air filtration application having medium dust holding capacity, made out from nonwoven synthetic media sandwiched between two layers of HDPE mesh assembled in aluminium frame supported by aluminium rod spacers to make it strong .These filters are washable and cleanable and are used as coarse filter to fine filter and also to protect the coil and HVAC system from dust loading. Available in standard depth of 50 mm. Other sizes are also made as per order. M.O.C is aluminium /G.I./SS304.
GRADE SIZE IN MM CFM CAPACITY INT.PRESSURE DROP % EFFICIENCY
EU-6/F6 610 X 610 X 150 1000 6 mm of WG 80
EU-6/F6 610 X 610 X 305 2000 6 mm of WG 80
EU-7/F7 610 X 610 X 150 1000 8 mm of WG 90
EU-7/F7 610 X 610 X 305 2000 8 mm of WG 90

HEPAFILTER

High efficiency particulate air filter (HEPA) is an absolute filter and is integral part of CLEAN ROOM. It is made out of borosilicate microfibers paper assembled in aluminum housing .A good resin bonding ensures no bypass of air between media and frame. These are available in EU-11 ,EU12,EU13,EU14 grade having minimum efficiency of 99.97% down to 0.3 micron. Standard depth is 150 and 300 mm..Other sizes are also made as per order.
GRADE SIZE IN MM CFM CAPACITY INT.PRESSURE DROP % EFFIC. AS PER MIL-282
EU-11 610 X 610 X 150 500 25 mm of WG 99.97
EU-11 610 X 610 X 305 1000 25 mm of WG 99.97

SUPERHEPAFILTER

SUPER HEPA FILTER is superior version of HEPA FILTER It is pleated with more media to take care of additional CFM drawn .A SUPER HEPA can handle double CFM in the same size when compared to normal HEPA filter. It is made out of borosilicate microfibers paper assembled in aluminum housing .A good resin bonding ensures no bypass of air between media and frame. These are available in EU-11 ,EU12,EU13,EU14 grade having minimum efficiency of 99.97% down to 0.3 micron. Standard depth is 150 and 300 mm..Other sizes are also made as per order.
GRADE SIZE IN MM CFM CAPACITY INT.PRESSURE DROP % EFFIC. AS PER MIL-282
EU-11 610 X 610 X 305 1000 25 mm of WG 99.97
EU-11 610 X 610 X 305 2000 25 mm of WG 99.97


VERTICAL LAMINAR AIR FLOW UNITS These are either ceiling suspended or stand mounted LAF used in clean rooms to protect the product from contamination ,generally installed above the filling ,filtration machines. to provide CLASS-100 cleanliness class. available in SS304/ G.I. powder coated constn. Standard size :3’ x 2’,4’x 2’, 4’x 3’, 4’ x 4’ other sizes can be made as per order.
REVERSE LAMINAR AIR FLOW UNITS(DISPENSING/SAMPLING BOOTH) These are vertical LAF units used in R.M.STORE of pharmaceuticals for dispensing and sampling of the powder. Fitted with side panels and vinyle strip curtains at entry .10% of air is exhausted from the unit to create negative pressure within the booth which ensures no powder spreading outside the booth. While CLASS-100 cleanliness provides protection of the material under process. available in SS304/ G.I. powder coated constn. Standard size :3’ x 2’,4’x 2’, 4’x 3’, 4’ x 4’ other sizes can be made as per order.
HORIZONTAL LAMINAR AIR FLOW UNITS These are Horizontal laminar flow units fitted with stand and table top , used in laboratories to protect the product from contamination while the product is under testing . Side acrylic or polycarbonate sheet ensures CLASS-100 cleanliness maintained throughout working table. U.v.light provided to kill microorganism. available in SS304/ G.I. powder coated constn. Standard size :3’ x 2’,4’x 2’. other sizes can be made as per order.
BIO-SAFETY CABINETS These are very useful in R & D /TESTING LABS. Where harmfulproduct is under testing to provide protection to product,operator and to environment . To achieve this these units are designed with utmost care. Negative pressure is maintained within the unit by exhausting 10% of air outside the unit.U.v. light provided to kill microorganism.Available in CLASS I, II, III of protection and CLASS 100( ISO-5) cleanliness. Standard size 3’x 2’, 4’ x 2’.other sizes can be made as per order.
OPERATION THEATRE MODULES O.T. MODULES are basically vertical laminar air flow units installed in operation theatres of hospitals to protect the patient from the harmful contamination .to ensure this these units are installed just above the O.T. TABLE .Collars are provided in the units to connect the ducting from the A.H.U. provision to pass O.T. light shaft from the unit . CLASS of CLEANLINESS 100 ( ISO-5) . Standard size 6’x 4’, 6’ x 5’, 7’ X 4’ ,7’ X 5’.other sizes can be made as perorder.
STATICPASSBOX Inside the clean zone materials need to be transferred from one grade of room to other. This demands the air to be restricted for transferring from one to other and prevent cross contamination.Pass boxes are made to solve this issue. These are airtight metal enclosures with 2 doors ,three doors configuration having electromagnetic or mechanical interlocking to prevent all doors opening at the same time. U.v.light also provided for killing microrganism.standard size: 1’ x 1’ x 1’ , 2’ x 2’ x 2’. Other sizes can be made as per order.
DYNAMICPASSBOX Some time while transferring the material within the clean rooms of different grades it becomes necessary to protect the material from contamination during transfer DYNAMIC PASS BOXES are very useful in this. These are having HEPA filtered air circulating within the working area providing CLASS 100 ( ISO-5) environment . Electromagnetic or mechnical interlocking prevents the door opening at same time. U.v.light provided to kill the microorganism. standard size: 2’ x 2’ x 2’ 3; x 3’ x 3’.other sizes can be made as per order. M.O.C. SS304/G.I.powder coated.
ULTRACLEAN - Air Systen & Technologies